# Console Commands Archive
Archived
This is for documentation only. The documentation for the latest version is available here.
# Available Commands v2.0036
- Available Commands v2.0036
- 1053
- battery
- compiled
- configure_bluetooth
- device_info
- digital_write
- expr
- flow_calibration_set_point
- flow_calibration_setting
- flow_calibration_value
- flow_off
- flow_v
- get_flow
- hall
- hello
- indicate
- indicate_off
- light
- memory
- on_5v
- p2p
- par_led
- print_all
- print_date
- print_magnetometer
- print_magnetometer_bias
- print_memory
- pulse
- readonce
- reboot
- reset
- reset_flow_calibration
- reset_flow_zero_point
- scan_i2c
- set_accelerometer
- set_accelerometer_bias
- set_colorcal1
- set_colorcal2
- set_colorcal3
- set_colorcal_blanks
- set_dac
- set_date
- set_default_flow_rate
- set_detector1_offset
- set_detector2_offset
- set_detector3_offset
- set_detector4_offset
- set_device_info
- set_energy_save_time
- set_flow
- set_led_par
- set_magnetometer
- set_magnetometer_bias
- set_open_closed_positions
- set_par
- set_serial
- set_shutdown_time
- set_thickness
- set_thickness_quick
- set_user_defined
- single_pulse
- sleep
- start_watchdog
- stop_watchdog
- tcs_length
- temp
- testmode
- upgrade
- usb
# 1053
Continuous feed of roll, pitch, compass, direction, tilt and tilt direction. Cancel the command with -1+
Example:
1053
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# battery
Test the instruments battery with load returning the charge state in percent (%)
Example:
battery
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# compiled
Returns date and time for when the Firmware was compiled.
Example:
compiled
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# configure_bluetooth
Set the bluetooth name and baud rate
Example:
configure_bluetooth
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# device_info
Receive information from the Instrument, including name, version, id, battery level, firmware and configuration.
Alias: 1007
Example:
device_info
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# digital_write
Asks for address location and output value (0 or 1) and sets the digital address to this value. This is a dangerous if you do not know what you are doing.
Input: [number]
Values:
- 0 + 1
Example:
digital_write
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# expr
Example:
expr
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# flow_calibration_set_point
Alias: fcsp
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# flow_calibration_setting
Alias: fcv
Example:
flow_calibration_setting
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# flow_calibration_value
Alias: fcv
Example:
flow_calibration_value
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# flow_off
Set air flow to zero
Example:
flow_off
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# flow_v
Example:
flow_v
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# get_flow
Example:
get_flow
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# hall
Continues output of the hall sensor readings. Stop output using the command -1+
Example:
hall
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# hello
Check if your instrument is connected. On success the response is Instrument Ready
.
Alias: 1000
Example:
hello
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# indicate
Sets the indicator LED (RGB LED). Values in the range from 0-255 need to be set for the Red, Green and Blue channel.
Input: [number]
Example:
indicate+<Red>+<Green>+<Blue>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# indicate_off
Turn off indicator LED
Example:
indicate_off
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# light
Turn on 5V to turn on a light. Replace the <light number> with the number of a light, e.g. light1
Example:
light<light number>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# memory
Returns the memory usage of the instrument.
Example:
memory
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# on_5v
Turn on 5V for 30 seconds
Example:
on_5v
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# p2p
Read multiple pulses with increasing intensity or pulse width for linearity test. With constant DAC value and pulse width, it is good for a pulse-to-pulse stdev test
Example:
p2p
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# par_led
Input: par_led
Example:
par_led
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# print_all
print everything in the eeprom (all values defined in eeprom.h)
Example:
print_all
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# print_date
Print date based on instruments RTC (if available).
e.g.2004-02-12T15:19:21.000Z
Example:
print_date
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# print_magnetometer
Example:
print_magnetometer
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# print_magnetometer_bias
Example:
print_magnetometer_bias
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# print_memory
Print all calibration values as they are saved to the instruments storage (EEPROM). Output is formated as a JSON with a checksum.
Alias: print_calibrations
Example:
print_memory
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# pulse
Example:
pulse
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# readonce
Access write once flash
Example:
readonce
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# reboot
Example:
reboot
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# reset
Reboot the instrument.
Alias: 1027
Example:
reset
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# reset_flow_calibration
Set air flow calibration to factory settings
Example:
reset_flow_calibration
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# reset_flow_zero_point
Example:
reset_flow_zero_point
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# scan_i2c
Scan for available i2c devices.
Example:
scan_i2c
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_accelerometer
Example:
set_accelerometer
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_accelerometer_bias
Example:
set_accelerometer_bias
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_colorcal1
Example:
set_colorcal1
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_colorcal2
Example:
set_colorcal2
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_colorcal3
Example:
set_colorcal3
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_colorcal_blanks
Example:
set_colorcal_blanks
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_dac
Set DAC addresses to 1,2,3 assuming addresses are unset and all are factory (0,0,0).
Example:
set_dac
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_date
Set the date of the RTC of the instrument (if available)
Example:
set_date+
hours+min+sec+day+month+year
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_default_flow_rate
Input: [number]
Example:
set_default_flow_rate+<number>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_detector1_offset
Example:
set_detector1_offset
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_detector2_offset
Example:
set_detector2_offset
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_detector3_offset
Example:
set_detector3_offset
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_detector4_offset
Example:
set_detector4_offset
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_device_info
Set the device name
Alias: 1008
Example:
set_device_info
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_energy_save_time
Input: [number]
Example:
set_energy_save_time+<number>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_flow
Input: [number]
Example:
set_flow
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_led_par
Example:
set_led_par
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_magnetometer
Example:
set_magnetometer
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_magnetometer_bias
Example:
set_magnetometer_bias
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_open_closed_positions
Input: set_open_closed_positions
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_par
Example:
set_par
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_serial
Example:
set_serial
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_shutdown_time
Sets the time (in seconds) before the device automatically shuts down to save energy.
Input: [number]
Example:
set_shutdown_time+<seconds>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_thickness
Example:
set_thickness
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_thickness_quick
Example:
set_thickness_quick
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# set_user_defined
Save a user defined value to the EEPROM. You can abort the input using -1+
.
Example:
set_user_defined+<EEPROM Location>+<value>
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# single_pulse
Read and analyze noise on ADC from a single LED pulse (only in testmode).
Example:
single_pulse
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# sleep
Puts instrument into sleep mode. Hold the button for at least 5s to wake it up.
Example:
sleep
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# start_watchdog
Example:
start_watchdog
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# stop_watchdog
Example:
stop_watchdog
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# tcs_length
Example:
tcs_length
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# temp
Return the readings for both BME280 sensors including temperature and relative humidity.
Example:
temp
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# testmode
Example:
testmode
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019
# upgrade
Start over the air firmware update. The instrument is waiting for the new firmware to be transfered to the instrument.
Alias: 1078
Example:
upgrade
Instruments:
MultispeQ 1
MultispeQ 2
Last Updated: December 17, 2019